Measures to avoid seepage and stagnation of water in Toilets 

Background:

Drain water from lavatory splashes over the Bogie / Under gear components when the train is in run which leads to corrosion of under gear components. Also there is problem of Stagnation of water in Toilets leading to unhygienic conditions.

Earlier Drain Hole

Water stagnation problem in Toilets

Gravity Cock With APD CCTV

Drain Hole Eliminated in New Coaches

Additional Stiffenings to avoid water stagnation

Gravity Cock With APD

Description:

To avoid water splashing drain holes in pan type lavatory have been eliminated. Additional stiffenings given in the inlay to minimize the drumming effect there by reducing the chances of water pockets.

Implementation Status at ICF:

Elimination of drain hole mplemented from 2013 and additional stiffenings introduced from 2015.